The Glycomic MS Database and Repository

Announcement date

2021/05/26

Responsible:

Niclas Karlsson . University of Gothenburg

Description

Released reduced O-glycans from brain tissue analyzed with graphitized carbon column and negative ion mode MS

Sample preparation


1. Sample Origin

General information:
PRG4 (lubricin) purified from synovial fluid from two patients with osteoarthritis


1.1 Biologically derived material

Biologically derived material - Recombinantly produced material

Cell type:
N/A

Growth/harvest conditions for recombinantly produced material:
N/A


Biologically derived material - Biological origin of Material

Origin (biological fluid, tissue, etc):
Synovial fluid

Species:
Homo sapiens

Treatments and/or storage conditions:
Glycoprotein isolation by anion exchange chromatography and ethanol precipitation

Glycoprotein:
Q92954


Biologically derived material - Purchased from commercial manufacturer

Vendor and applicable item information:
N/A


1.2 Chemically derived material

Synthesis steps or specify where the equivalent reaction protocol is available:
N/A

Description of starting material:
N/A


2. Sample Processing

2.1 Sample Processing - Isolation

Enzymatic treatments

Enzymes used for oligosaccharide removal or modification of starting material:
Trypsin

Describe vendor or expression and purification procedure:
Promega

Sample material treated in-solution or immobilized? State also temperature, duration, volume, enzyme concentration:
In-solution


Chemical treatments

Define the technique for oligosaccharide release or other chemical modifications:
Reduction, alkylation with iodacetamide

Reaction conditions (temperature, duration, volume and chemical concentrations):
N/A


2.2 Sample Processing - Modification

2.3 Sample Processing - Purification

Purification steps:
Tryptic glycopeptides were purified with C18 ziptip


3. Defined Sample

Sample name:
Glycopeptides




Liquid chromatography


N/A



MS


1. General features

(a) Global descriptors

Instrument manufacturer:
Thermo Fisher

Instrument model:
LTQ Linear Ion Trap

Customizations:
N/A

Ion mode:
Negative


(b) Control and analysis software


2. Ion sources

(a) Electrospray Ionisation (ESI)

Supply type (static, or fed):
Liquid Chromatograhpy

Interface name:
N/A

Catalog number, vendor, and any modifications made to the standard specification:
Thermo Fisher Electrospray

Sprayer name:
Electrospray

Sprayer type, coating, manufacturer, model and catalog number (where available):
Thermo Fisher metal needle

Relevant voltages where appropriate (tip, cone, acceleration):
Source Voltage 2.6 kV, Capillary Voltage -37 V

Degree of prompt fragmentation evaluated:
Yes

Whether in-source dissociation performed:
No

Other parameters if discriminant for the experiment (such as nebulizing gas and pressure):
N/A


(b) MALDI

Plate composition (or type):
N/A

Matrix composition (if applicable):
N/A

Deposition technique:
N/A

Relevant voltages where appropriate:
N/A

Degree of prompt fragmentation evaluated:
N/A

PSD (or LID/ISD) summary, if performed:
N/A

Operation with or without delayed extraction:
N/A

Laser type (e.g., nitrogen) and wavelength (nm):
N/A

Other laser related parameters, if discriminating for the experiment:
N/A


3. Ion transfer optics

Hardware options:
N/A


(a) Post-source componentry - Collision cell

Collision-Induced Dissociation (CID)

Gas composition:
He

Gas pressure:
N/A

Collision energy CID/function:
Normalised energy 35


Electron Transfer Dissociation (ETD)

Reagent gas:
N/A

Pressure:
N/A

Reaction time:
N/A

Number of reagent atoms:
N/A


Electron Capture Dissociation (ECD)

Emitter type:
N/A

Voltage:
N/A

Current:
N/A


(b) Post-source componentry - TOF drift tube

Reflectron status (on, off, none):
N/A


(c) Post-source componentry - Ion trap

Final MS stage achieved:
MS2


(d) Post-source componentry - Ion mobility

Gas:
N/A

Pressure:
N/A

Instrument-specific parameters:
N/A


(e) Post-source componentry - FT-ICR

Peak selection:
N/A

Pulse:
N/A

Width:
N/A

Voltage:
N/A

Decay time:
N/A

IR:
N/A

Other parameters:
N/A


(f) Post-source componentry - Detectors

Detector type:
Electron multiplier